Ignition Coil Testing “Waste spark ignition system”:

Ignition Coil Testing “Waste spark ignition sytem”:

1.) Remove the secondary ignition wire , set your DMM on the ohms scale, then insert the probes as shown. Secondary resistance between coil secondary terminal 1 and terminal 2 should be 21.0 K ohms ±15 percent.

2.) Move the DMM leads to coil secondary terminals 3 and 4. Resistance between these terminals should also be 21.0 K ohms ±15 percent.

3.) The next step is to measure the ignition coil primary resistance. Disconnect the ignition coil harness connector. The specified primary resistance between harness connector terminals 1 and 2 is 0.69 ohms ±10 percent.

4.) Move the DMM leads to terminals 2 and 3. Primary resistance between these terminals should also be 0.69 ohms ±10 percent.

5.) A resistance reading of the insulation between any primary terminal and the coil case should be 10M ohms or more. A lower resistance reading indicates that the coil primary windings are shorted to ground.

If your coil pack is defective it’s best to get a new coil pack.


Brand New Ignition Coil Pack For 1997-1999 Subaru Impreza And Legacy 2.2L 2.5L H4 OEM Fit C193

Brand New Ignition Coil Pack SUBARU 2.5L 4cyl H4 SOHC Complete Oem Fit CAA50

Brand New Ignition Coil Pack SUBARU 2.5L 2.0L Complete Oem Fit C324